Twin line pumping group for solar systems
Main technical data
Technical data:
Dimension :L42cm×W28cm×H14cm
Power Consumption?< 4W
temperature measuring±2C
Range of collector temperature measuring?-10?200?C
Range of tank temperature measuring?0?100?C
Suitable power of pump:4pcs,< 600W
Suitable power of electrical heater:1pc,<1500W
Input:
One Sensor for collector (pt1000,probe≤500oC,Silicon cable≤280?C)
Two Sensors for tank (pt1000,probe≤135?C,pvc cable≤105?C)
working ambient temperature?-10?50oC
Water proof grade?IP43
Main functions
DTO & DTF Temperature difference controlling the Solar circuit pump
THET--Timing heating
EM -- Emergency collector temperature emergency switch off
CMX -- Maximum limited collector temperature(collector cooling function)
CMN --low temperature protection
CFR --frost protection
SMX -- Maximum temperature protection on tank
REC -- Tank re-cooling function
DVWG --Anti-Legionella function
CIRC --temperature controlled CIRC hot water circuit pump
CIRC time controlled CIRC hot water circuit pump
nMIN Solar circulation pump speed adjusting(RPM speed controlling)
Digital flow meter
OHQM Thermal energy measuring
INTV Pump interval fucntion
Auxiliary function:
a, heating return rising, b. temperature controling, c: high temperature reducing. d: by-pass pipe
Holiday function
HND Manual mode
PASS Password setting
LOAD Recovery to factory setting
Manual Heating
Temperature query function
Memory Protection
Screen protection
Trouble protection
ebus function(far distance controlling by keypad with display)